SHANGHAI YANYE INDUSTRIAL EQUIPMENT CO.,LTD

We provide For Safe,Saving,And sustainable Cooling Solution !!

Be the best global cooling leader!

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsAmmonia Evaporative Condenser

Closed Cooling Tower Ammonia Evaporative Condenser With Stainless Steel Pipe

Good quality Closed Cooling Tower for sales
Good quality Closed Cooling Tower for sales
I'm Online Chat Now

Closed Cooling Tower Ammonia Evaporative Condenser With Stainless Steel Pipe

China Closed Cooling Tower Ammonia Evaporative Condenser With Stainless Steel Pipe supplier
Closed Cooling Tower Ammonia Evaporative Condenser With Stainless Steel Pipe supplier Closed Cooling Tower Ammonia Evaporative Condenser With Stainless Steel Pipe supplier Closed Cooling Tower Ammonia Evaporative Condenser With Stainless Steel Pipe supplier

Large Image :  Closed Cooling Tower Ammonia Evaporative Condenser With Stainless Steel Pipe

Product Details:

Place of Origin: SHANGHAI/JIANGSU
Brand Name: YANYE /BAOFENG/Jiangfan
Certification: ISO 9001 2008/CTI
Model Number: YCT/YNT/YHT/CLA

Payment & Shipping Terms:

Minimum Order Quantity: I UNIT
Price: Negotiation
Packaging Details: PALLET WITH FILM WRAPPING FOR CONTAINER OCEAN TRANSPORT
Delivery Time: 70 days
Payment Terms: T/T, L/C
Supply Ability: 380 unit /month
Contact Now
Detailed Product Description
Shell: Alum-zink Galvanized Steel Plate (S.Korea) δ=2mm Cooling Coil: Hot Dip Galvanized Seamless Carbon Steel Coils∮=25mm δ=2.0mm
Water Basin:: 304 SS Steel Plate Electrical Components: Schneider Brand
Spray Pump: Cast Iron(SIEMENS) Motor Grade:: IP55 Insulation: F
Refrigerant Liquid: Ammonia /R717/R22 Power Supply: 380v /3P/50HZ
Spare Parts: Depending On The Circumstances
High Light:

bac evaporative condenser

,

ammonia condenser

Ammonia Condenser Industrial Cooling Equipment NH3 Evaporative condenser R717 Evaporative Condenser R22 Evaporative:

 

2.1.1 Wind Cooling:

YZFL series evaporative condenser uses water and air as  Cooling agent.The cooling agent exchanges the heat with

High temperature gaseous refrigerant agent and hence the

refrigerant agent becomes liquid.inside it has a water

distribution system, condensing coils,wet deck ,dehydrator and

so on. Outside it has a water circulating pump , a propeller fan

on the top of condensing coil. The propeller fan strengthens

the flow of the air and causes negative pressure inside.

when the condenser runs,the cooling water is pumped and

then sprayed by water distribution system On the surface of

condensing coil equably to form a thin layer of water film.

 

2.1.2 Water Cooling:

The high –temperature steam of refrigerant agent enters from the top of condensing coil and then the cooled liquid refrigerant agent is discharged from the bottom of the condenseing coil .during this process,high temperature refrigerant agent exchanges the heat with the water and air outside the coil and increases the the effect of heat exchange with the help of wind .after aborbing the heat of refrigerant agent .some water turns into steam and is discharged by fan .meanwhile,the moisture in the

Air is collected by dehydrator to basin.and the ungasified cooling water flows into wet deck and its heat is taken away by the airflow .the cooled water converges in the basin to be used circularly by the pump.

In addition,there is a ball cock in the basin .when the water is consumed to a certain point the ball cock

Will automatically open to replenish the cooling water.

 

2.2 Evaporative Condensers Configuration and Technical Performance

 

The evaporative condensers main machine consists of shell, cooling coils, air discharge system, spray system, drift Eliminator and water basin etc.

  • Drift Eliminator (standard): The main function of the Drift Eliminator is to recollect the vapor water after the cooling process for reuse in the following circulation. YANYE  exclusive high efficiency Drift Eliminator, by three-times changing air movement current, reduces the spray water drift rate to as small as 0.001%, making it ideal for application at fog sensitive areas.

 

  • Water Collector(standard): The main function of water collector is to collect spray water. It consists of water basin, float bulb valve, water inlet, water drain outlet, foul drainage outlet, spray pump water inlet and filter net etc parts.
YZFL-330F Specifications
Heat Reject :330 kw
Gas Filling Rate :35 kg/minute
Power of fan :1× 4.0 kw
Blowing rate: 1× 65000 m3/h
Spray Pump’s Delivery Lift :10 m
Spray Pump’s Power : 2.2 kw
Spray Water Flow Rate : 44.7 m3/h
Drift Loss : 0.01% m3/h
Operation Work Pressure: 0.10—0.35 Mpa
Inet/ Outnet: 1*DN 100mm/ 1*DN 100mm
DN100:Liquid outlet (Please specify adopted screw standards)
DN100:Air inlet (Please specify adopted screw standards)
Compensation water pipe: DN 25 mm
Discharge pipe: DN 50 mm
Overflow pipe: DN 80 mm
Shipping Weight: 1860 kg
Operating Weight:2860kg
2280mm×2300mm×3720mm (L*W*H)

 