Product Details:
Payment & Shipping Terms:
|
High Light: | open circuit cooling tower,open loop cooling tower |
---|
Personnel Health Protection
Open cooling water system is subject to water pollution and, as a result, the bacteria of miscellaneous sorts proliferate fast to become a grave threat to human health by dissipating the bacteria containing vapor. A popular disease from open water cooling system is legionnaire that endangers human life by causing pneumonia, which is especially true for people living & working in the buildings with central air conditioners. Closed circuit cooling tower has the largest proportion of cooling water circulating inside enclosed loop, thus is not subject to water pollution. The specially designed louvers not only reduce the limited spray water drift to minimum level, but also effectively stop outside sunlight and particles from entering the tower basin cultivating the growth of bacteria.
Tube Scaling
PreventionMost scaling & fouling problems are caused by impurities brought into cooling tubes by process cooling water, which will easily damage heat rejection equipment like melting furnaces, some cases of which involve personnel safety issues. For other equipments like central air conditioner, generators, compressors etc, scaling problems are one of the main reasons for lower operation efficiency and souring maintenance cost. Closed circuit cooling tower eliminates the scaling problems by running de-mineralized process water inside the closed circuit cooling coils so that scaling problem is reduced to the lowest level if not completely eradicated.
Energy Saving
Variable frequency control ( VFC) is an option for flexible adjustment of the number and speed of working cooling fans to ambient temperature changes, the data of which can be preset at a certain figure. During winter season, the spray water stops automatically when ambient temperature drops to a certain level using only a set number of operating fans to satisfy the reduced cooling requirements.Water SavingCCCT system adopts 100% closed circuit circulation for process fluid that saves water from loss in any form. Special baffle is used to reduce unavoidable spray water loss to the lowest point without negative impact on the cooling efficiency. The prominent water saving nature is one of the most important factors deciding the popular use of closed circuit cooling tower.Space SavingClosed circuit cooling tower is designed to operate within very limited space, accounting for 1/4-1/5 that of open cooling system, saving any form of ground construction. The effective drift eliminator baffle enables closed circuit cooling towers to be used indoors close to production line without wetting the groud.
Investment Saving
Closed circuit cooling tower has self-attached water basin and fully enclosed cooling coils for preservation of cooling water that saves any form of ground construction cost. Under open cooling tower system, the large water pool is a necessity to supply all process cooling water, and the related investment will be of no use if the open cooling tower is to be re-installed to a different site.
User Friendly
YANYE closed circuit cooling tower can be controlled via remote control panel with clearly defined functional push-buttons and digital display system. Automatic Light & Sound alarm system is installed to remind the operator of extreme working conditions of the cooling system for on time adjustment; VFC technology is available for automatic setting of the cooling tower operation data following ambient changes without human interference. Computer control system is also possible under highly sophisticated cooling system requirements.Longer Life ExpectancyInstead of adopting wooden structure or PVC cooling fills, closed circuit cooling tower is composed of copper or carbon steel cooling coils, zink-aluminum galvanized steel case and stainless steel structures etc that prolongs the trouble-free service life of closed circuit cooling tower.
Easy Installation and Maintenance
The installation of closed circuit cooling tower includes merely the connection of piping and electrical system that can be done even by technical workers without training.
Due to the scaling-free nature of closed circuit cooling tower, a great deal of human efforts for monthly or quarterly maintenance can be saved, which are normally neglected due to the busy production schedule and tend to cause sudden stop with long accummulation of scalings.
ITEM | Description | |
Summarization | Type | Square Cross Flow Open Cooling Tower |
Model | CLA-150B-1 | |
Quantity | 1 Units | |
Noise | Standard Low Noise Open cooling Type ≤ 60 db(A) @ 20 M | |
Operating Conditions | Total Flow Rate Requested | 129.6 m3/h= 36L/S |
Single Flow Rate Per Tower | 150 m3/h *1 Unit | |
Inlet Temperature | 34 ℃ | |
Outlet Temperature | 29 ℃ | |
Wet Bulb Temperature | 20 ℃ | |
Temperature Drop | 5.0 ℃ | |
Operation Work Pressure | 100.4kPa | |
Drift Rate | ≤ 0.001% | |
Structure Section | The Tower’s Dimension | 4000mm*2600mm |
Tower’s Height | 3250mm | |
Tower’s Quantity | 1 Units | |
Ventilator’s Quantity | 1 Unit/ per tower | |
Ladder | One side have the ladder | |
Access Door | One side have the door | |
Material of Construction | Upper Body | (F.R.P) |
Under Body | (F.R.P) | |
Water Pond | (F.R.P) | |
Water Sump Tank | (F.R.P) | |
Louver | (F.R.P) | |
Tower Top | (F.R.P) | |
Water System | Q235-A Pickling, Hot Dipped Galvanized steel | |
Spray Nozzles | ABS | |
Spray Nozzles’s Type | ABS basket nozzles’s of umbrella style |
▲ Power Saving, Water Saving
In the spring season or winter season,it don’t need open fan system for cooling.
So it’s will reduce the operating cost .high efficiency PVC filling, lower evaporation,
Less dirty, easy to clean and maintenance.
KEJU Cooling Tower comes with large capacity water pool. users don’t have the pool Excavation. Sewage cleaning is convenient .
Modular design, flexible layout according to the users site, an area of small, long life
High efficiency, low consumption, low leaching .
PVC packing with high efficiency, high cooling rate, but also has guided the wind, the water collection function, low resistance, low energy consumption.
Meet the national standard GB7190.1-1997 low-noise targets.
▲ Product variety Cooling
The cooling requirements applicable to different environments, for a wide range of
Variety cooling conditions.
Contact Person: Peter.Zeng
Tel: +8613918233461