Product Details:
Payment & Shipping Terms:
|
Shell: | Galvanized Steel Plate (S.Korea) | Water Basin: | 304 SS |
---|---|---|---|
Power Supply: | 380v/3p/50hz | Fan Blades: | IP55; Insulation: F; Alum-alloy Blades; Axial Flow |
Warranty Period: | 20 Month | Wind Louvre: | Anti-corrosion; Sun Sheltering; Drift Elimination |
Spray Nozzles: | ABS Basket Nozzles Of Umbrella Style | Flange: | Stainless Steel |
High Light: | bac closed circuit cooling tower,industrial process cooling system |
Cooling tower parts Industrial Cooling tower parts Cooling tower parts Closed Cooling tower parts :
Advantages for cooling towers:
1) Closed loop
Preventing the impurities into the system to block the cooling tubes, soft water is adopted to avoid overheating caused by scaling to the water pipes.
2) Automatic temperature control
Automatic start/stop spraying system to achieve effective control on the temperature of cycled cooling water, the temperature of the cooling water can be controlled below 40 ℃. With this function, the water & energy cost is reduced to the lowest point with intelligent control to the number of working fans and start & stop of spray pump.
3) No need of water pool and cooling tower
Low cost, small space occupancy, easy installation and move with the welder.
4) Automatic digital display of temperature control
Energy efficient and user friendly.
5) Cooling system structure
Galvanized iron beam.
proportions, please consult your WELL representative.
Glycol (wt%) | 0 | 10 | 20 | 30 | 40 | 50 | 58 | 80 | 90 | 100 |
Congreal (C) | -0.0 | -3.5 | -8 | -15 | -24 | -36 | -48 | -47 | -29 | -13 |
Methanol is poisonous, and enough care must be taken for safe operation
Methanol and Ethanol is volatile, and after long term use, the density may decrease. Below 30% mixture ratio provides lowest volatile level and could be effective in the case of -20℃
For external circulation that relates to spray system, certain measures shall be taken to avoid the spray water from getting frozen in the basin. Electrical immerse heater is recommended for this consideration.
The spray pump also needs to be protected against cold weather, and this may concern the thermal materials like saw dust etc.
Note: All chemical addictives must be compatible with the equipments and piping systems!
Model | KBL-07 |
Operating Conditions | |
Nominal Flow Rate (m3/h) | 120 |
Inlet/Outlet DN (mm) | 50 |
Water Makeup/Bleed-off DN(mm) | 25 |
Cooling Capacity (Kcal/h) | 225000 Kcal/h |
Unit Heat Rejection (KW) | 261 kw |
Unit Fan Motor (KW) | 1.5 kw*2 |
Unit Airflow (m3/h) | 16800*2 |
Spray Pump’s Delivery Lift (m) | 10 |
Spray Pump Power (KW) | 1.10 kw |
Spray Water Flow Rate (m3/h) | 22 m3/h |
Main Water Pump’S Delivery Lift (m) | 32 |
Main Water Pump’S Power (KW) | 7.5 |
Main Water pump’s Flow Rate (m3/h) | 50 |
Operation Work pressure | 0.10--0.35 Mpa |
Unit Dimension L × W × H (mm) | 2500*1250*2350 |
Shipping Weight (kg) | 1400 |