Product Details:
Payment & Shipping Terms:
|
Water Basin: | 304SS Steel Plate | Shell: | Alum-zink Galvanized Steel Plate (S.Korea)δ=2 Mm |
---|---|---|---|
Power Supply: | 380V/3P/50HZ | Water Eliminator: | Anti-corrosion PVC |
Spray Pump: | Cast Iron(Schneider) | Temperature Controller: | Standard |
Fan: | Alum-alloy Blades; Axial Flow | Spare Parts: | As Per Actual Situation |
Flange: | Stainless Steel | ||
High Light: | closed circuit cooling tower,closed loop cooling tower |
Industrial Cooling Coil water Cooling Coil Heat exchange Cooling Coils Evapco Cooling tower Coils BAC Cooling coils:
YZFL-780F Specifications |
Heat Reject :780 kw |
Gas Filling Rate :35 kg/minute |
Power of fan :1× 4.0 kw |
Blowing rate: 1× 65000 m3/h |
Spray Pump’s Delivery Lift :10 m |
Spray Pump’s Power : 2.2 kw |
Spray Water Flow Rate : 44.7 m3/h |
Drift Loss : 0.01% m3/h |
Operation Work Pressure: 0.10—0.35 Mpa |
Inet/ Outnet: 1*DN 100mm/ 1*DN 100mm |
DN100:Liquid outlet (Please specify adopted screw standards) |
DN100:Air inlet (Please specify adopted screw standards) |
Compensation water pipe: DN 25 mm |
Discharge pipe: DN 50 mm |
Overflow pipe: DN 80 mm |
Shipping Weight: 1860 kg |
Operating Weight:2860kg |
2280mm×2300mm×3720mm (L*W*H) |
description
1. closed cooling towers are Using the counter flow cooling way; few cooling blind area, high thermal efficiency:
2. Efficiency of cooling tower is to adopt the professional and efficient water collector to control the running floating rate ,that is less or equal to 0.001%;
3. Closed cooling tower in high air duct design to make sure the equipment to meet the demand of cooling air flow rate during operation;
4. Reduce the occupied area compare to other types of cooling tower to meet the users' space demanding;
5. The tank of cooling tower adopts closed loop, eliminate clutters go into the tower body to produce spraying blocked;
6. The important part of counterflow cooling tower is the cooler that uses the antifreeze energy-saving design, to ensure the circulating water drain up and avoid freezing in the northern region with low temperature;
7. Design two-circuit cycle according to the demands of custom's devices, even if one circulation failure, anther cycle can be still normally operating;
8. The cooling tower design of units are elegant appearance, automatic digital display, easy to maintain.
Our Services
For new and old import and export customer supply:
1. A professional sales team,experienced engineers, advanced manufacturing equipment,particular production technology;
2. Supply specialized installation guidance and after services that anytime and any country if customer need.
3. Reply your inquires within 24 hours anytime and anywhere.
Contact Person: Peter.Zeng